-40%

Kee Gold Tester “The Prospector"(Gold & Platinum Analyzer) M509-GM KGA

$ 171.6

Availability: 19 in stock
  • All returns accepted: Returns Accepted
  • Item must be returned within: 14 Days
  • Certification: Uncertified
  • New or Used: New
  • Return shipping will be paid by: Buyer
  • Condition: New in box with Tester, Wand, File
  • Brand/Mint: Kee Gold
  • Refund will be given as: Money Back
  • Restocking Fee: No

    Description

    You are buying a:
    Kee Gold Tester - The Prospector (M-509GM)
    KGA(Kee Gold Analyzer) Unit Meter
    Assembled in the USA:
    Gold & Platinum Analog Meter Tester
    Easily tests 10K 14K 18K 22-24K & Platinum
    Portable and Fast!
    Upgraded Unit
    This comes with the October 2016 Upgrade
    1) Greater Testing Stability
    2) Enhanced Wand Efficiency
    3) Longer Battery Life
    Comes ready to use, operates with one AA
    . Battery Included, testing file included
    The UNITED STATES PATENT # is  US 8,211,366 B2 and was issued on July 3, 2012.
    Includes Kee Gold Analyzer, New (+) Testing Wand w/polisher Cap, (-) Testing Probes
    Please see other listings for replacement parts and wands.
    Kee Gold Analyzer Instructions:
    Always!
    1) Turn Kee Gold Analyzer (KGA) off when not in use (battery will die)
    2) Keep Cap snapped on Wand when not in use (Wand will dry out)
    Basic Instructions:
    1. Turn KGA on
    2. Remove Cap from Wand
    3. Calibrate KGA with known piece of 18K (not included), set meter to center of white zone.
    4. Test items
    5. Replace Cap to Wand and Turn KGA off when done.
    Better Calibrating Instructions:
    1. With KGA off, adjust meter needle to bottom of red zone using the meter adjustment screw
    2. Turn KGA on,
    3. Calibrate Unit with known piece of 18K, set meter to center of white zone using large knob.
    4. Meter needle should be within or beyond the grey zone when on, adjust with large knob on right of KGA and retest 18K
    5. The meter needle should now have full range of the meter
    6. If the meter will not calibrate at room temperature, change the battery.
    Changing the battery:
    1. Turn KGA off and remove testing wand and wires.
    2. Remove protective rubber cover.
    3. Remove two Phillips screws
    4. Gently pull KGA apart
    5. Replace the one AA Battery with a fresh one (lithium preferred), reassemble
    Things to Know:
    1) KGA works best at room temperature.
    2) Replacement Wands cost .00 plus tax(Colo).
    TO GET STARTED:
    Plug red lead wire into either "slot E or slot G" on the meter.
    Plug black lead wire into "slot F" on meter.
    Turn on meter at location "B".
    Calilbrate meter "C" to center of 18k zone, while testing a known peice of 18k
    Polish gold to be tested with tip from testing probe "P".
    Place gold on integrated test plate "D" or clip with allligator tip "L".
    Place contact tip of pen "Q" on gold at (3) three different areas,
    concentrating on a "high wear area".
    If you get different readings each time, use the polishing tip or file and retest.
    FAQ: How do I calibrate my meter?
    Calibrating your meter is easy. All you need to do is test a piece of known 18k gold, and while testing, turn the adjusting knob until the meter needle is centered in the white 18k zone.
    Why won’t my meter calibrate to 18k anymore?
    When your meter will not calibrate to 18k, it normally means the battery needs to be replaced. Please follow the directions for “replacing battery” in the Q&A section. It can also mean the probe needs replaced this will depend on usage and probe care. Always replace battery first.
    (Note: If the probe is left with cap off, this will greatly reduce the life of the probe.)
    How do I change the battery?
    First remove the black rubber protective case from the meter body. Remove the 2 phillips head screws from the back of the case. Replace the single AA battery and reassemble.
    (Note: because of the unique operating system of this meter, use only new, fully charged batteries! Lithium are recommended)
    How Long will my testing probe last?
    This all depends on use. We expect the test probe to last several months. If the meter is only used occasionally, the life span will be increased. Leaving the cap loose or off will greatly reduce the life of the probe.
    Why is this meter analog instead of digital?
    Although digital is the latest technology, it is not always suitable for all conditions and jobs. Because of the delicate nature and variables of testing gold, we at KEE Gold decided that a quality analog meter movement is a better fit for this job. Analog movements show all the different variables that can be found testing gold and gold plate. This gives the user an easy to see needle, that can become very quick to read and understand.
    If you are bidding on more than one item, email us through ebay when you are done and we will invoice you with an item total and a combined shipping price.
    Please do so before payment as we can not combine or change shipping amount after payment is made.We allow up to seven days of auctions to combine. Colorado residents add 4%, Denver residents add 8.31% tax, check out all our other items, Good Collecting on eBay, Coloradolabels
    _gsrx_vers_779 (GS 7.0.4 (779))